A global report published by the World Economic Forum points to a new "world order characterized by greater instability, polarizing narratives, eroding trust, and insecurity.
A vulnerability classified as critical was found in Cayman DSL Router. This vulnerability affects unknown code of the component ICMP Packet Handler. The manipulation leads to denial of service.
This vulnerability was named CVE-2000-0418. The attack can be initiated remotely. Furthermore, there is an exploit available.
It is recommended to apply restrictive firewalling.
A vulnerability classified as critical has been found in Drbenhur DBHcms 1.1.4. Affected is an unknown function of the file index.php. The manipulation of the argument editmenu leads to sql injection.
This vulnerability is traded as CVE-2010-4869. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
A vulnerability, which was classified as problematic, has been found in Themewinter WPCafe Plugin up to 2.2.22 on WordPress. Affected by this issue is some unknown functionality. The manipulation leads to missing authorization.
This vulnerability is handled as CVE-2023-47805. The attack may be launched remotely. There is no exploit available.
A vulnerability classified as very critical was found in NI LabVIEW up to 22.3.3/23.3.4/24.3.1. Affected by this vulnerability is an unknown functionality of the file HeapObjMapImpl.cpp of the component VI Handler. The manipulation leads to improper validation of specified index, position, or offset in input.
This vulnerability is known as CVE-2024-10494. The attack can be launched remotely. There is no exploit available.
A vulnerability, which was classified as very critical, has been found in NI LabVIEW up to 22.3.3/23.3.4/24.3.1. Affected by this issue is some unknown functionality of the file fontmgr.cpp of the component VI Handler. The manipulation leads to improper validation of specified index, position, or offset in input.
This vulnerability is handled as CVE-2024-10495. The attack may be launched remotely. There is no exploit available.
A vulnerability, which was classified as very critical, was found in NI LabVIEW up to 22.3.3/23.3.4/224.3.1. This affects the function BuildFontMap of the file fontmgr.cpp of the component VI Handler. The manipulation leads to improper validation of specified index, position, or offset in input.
This vulnerability is uniquely identified as CVE-2024-10496. It is possible to initiate the attack remotely. There is no exploit available.
A vulnerability, which was classified as problematic, has been found in WPBits WPBITS Addons for Elementor Page Builder Plugin up to 1.5.1 on WordPress. Affected by this issue is some unknown functionality. The manipulation leads to cross site scripting.
This vulnerability is handled as CVE-2024-56285. The attack may be launched remotely. There is no exploit available.
A vulnerability was found in Siemens Solid Edge SE2024 up to 224.0 Update 4 and classified as critical. Affected by this issue is some unknown functionality of the component ASM File Handler. The manipulation leads to heap-based buffer overflow.
This vulnerability is handled as CVE-2024-54093. The attack may be launched remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Siemens Solid Edge SE2024 up to 224.0 Update 4. It has been classified as critical. This affects an unknown part of the component PAR File Handler. The manipulation leads to heap-based buffer overflow.
This vulnerability is uniquely identified as CVE-2024-54094. It is possible to initiate the attack remotely. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Siemens Solid Edge SE2024 up to 224.0 Update 10. It has been declared as critical. This vulnerability affects unknown code of the component PAR File Handler. The manipulation leads to integer underflow.
This vulnerability was named CVE-2024-54095. The attack can be initiated remotely. There is no exploit available.